topRepair process

Standard Repair         

Step Item Status
Before action
Who Actions
1 Broken unit
Stored
CERN
LPC
Analyse EPC-DB-Logbook ("RPMBD%" in Eqt).
▶ Write EPC-DB-Repair as follow (ex:103466):
▶ Repair.Problem = summarize info.
▶ Repair.Solution = proposed action.
2 Broken unit
Stored
CERN
LPC
Repair unit & create / store repair procedure.
4 Repaired unit
Not fully tested
CERN
LPC
Perform the interlock tests.
▶ Repair.Validation = Interlock results.
5 Repaired unit
Not fully tested
CERN
LPC
Perform auto tests (cycles) (ROG How to?).
▶ use RPMBD.sh (default launcher = heatrun)
▶ Repair.Solution = Intermediate cycles results.
(Templates exist to diagnose results if test fails).
6 Functional unit
Not calibrated
CERN
LPC
Store unit with repaired not calibrated units.
7 Functional unit
Not calibrated
CERN
LPC & HPM
Arrange a calibration with HPM.

Repair process of a known failure, profiting from existing procedure.